Auto Save with Alphacam

Q.  A current active Alphacam drawing wasn’t saved prior to a system failure on the computer with Alphacam running and installed on it.  Can you help?

A. Yes, it is called Auto Save. 

Open Alphacam, go to File-Configure-Folders, and then select the General tab. 

This tab shows the current location of the Auto Save folder.  For this example it is located in the C:\LICOMDIR folder.  You have the option to map this folder to any location on the computer or any existing network location desired.

autosave1.jpg

Go back to File-Configure-General. On the Settings tab, you will see Auto Save Intervals [Minutes].  By default, this is set to 5 minutes.  This can be adjusted to any interval of minutes desired.

autosave2.jpg

Once the location of the Auto Save folder is known, go to File-Open, and locate the Autosave folder.  
In this folder there should be three files, 1.ard, 2.ard and 3.ard.  
The 3.ard file is the most recent file that has been Autosaved and the 1.ard file is the oldest.

autosave3.jpg

Please note:  If using a network license and sharing the Licomdir and the Licomdat folders with multiple users, it is recommended that each user maps to an Autosave folder on each individual local computer.
 

CKCA Spring Regional Meeting

Southern - Ontario
6/12/12

 

Homag & Planit Monthly Event

Mississauga, ON
5/4/12 - 8/3/12

 

CKCA Fall Regional Meeting

Lethbridge, Alberta
9/25/12

 

Vero Hosts Largest Ever Reseller Conference
5/18/12

 

Radan 2012 Solution for Offline Press-Brake Programming
10/17/11

 

Aspire to Stunning CNC Carvings
8/4/11

 

 

About Planit

Planit is a leading developer of software products servicing the woodworking, stone, and metal fabrication industries. As the world's largest provider of CAM software, Planit's brand portfolio includes Alphacam, Cabinet Vision, Cabnetware, Edgecam, Javelin, Jobsite Companion, MCS, Radan, and S2M Center.